Features
- High Accuracy measuring
Linearity: better than 0.5%, Repeatability: better than 0.2%, Accuracy: better than ±1% - Wide Measuring Range
Several types transducer for selection, measuring pipe size from DN 15mm to DN 6000mm - High Protection Grade
Protection grade of primary meter is IP68, can work in 2m of water - Easy to Operate
Browse data with magnetic stick on primary meter or reset parameter on secondary meter - Multi-display
Integrate signal detecting and flow measuring on primary meter, display accumulated/instantaneous flow, velocity in circle; secondary meter can also display over 100 menus - Far Transmission Distance
Connect primary and secondary meter through RS-485 interface, normal cable replaces special cable, transmission distance up to 1000m . Solve the problems of high cost of special cable, poor anti-interference, short transmission distance etc.
Optional Main unit
Functional Type LRF -2000F | Add the following function except above ones:
|
|
|
|
|
Wall-mount(LRF-2000FW)
| Panel-mount (LRF-2000FS)
| Explosion-proof (LRF-2000FD)
|
Optional transducer
| Feature | Functional Type |
| Clamp-on transducer | LRF-2000FNB |
| ![]() |
| Insertion transducer | LRF-2000FNC |
| ![]() |
| Prover Section | LRF-2000FNG |
| ![]() |
General Specification
Optional Transduers | Model | Measuring Range | Liquid Temperature | Accuracy | |
Clamp-on | TS-2(small size) | LRF-2000BNB1 | DN15 -100mm | -30C ° ∼ 90C ° | Better than ±1% |
| TM-1(medium size) | LRF-2000BNB2 | DN50 -1000mm | ||
TL-1(large size) | LRF-2000BNB3 | DN300 -6000mm | |||
High-tem clamp-on | HTS-1(small size) | LRF-2000BNB4 | DN15 -100mm | -30C ° ∼ 160C ° | |
| HTM-1(medium size) | LRF-2000BNB5 | DN50 -1000mm | ||
Insertion | TC-1(standard) | LRF-2000BNC1 | DN80 -6000mm | -40C ° ∼ 160C ° | |
| TLC-2(lengthen) | LRF-2000BNC2 | |||
Prover Section | Prover Section | LRF-2000BNG | DN15 -1000mm | -40C ° ∼ 160C ° | Better than ±0.5% |
| |||||
Power Supply | Main unit: 8-36VDC , long distance display meter: AC220V or DC24V | ||||
Input | 3 channel 4-20mA analog input, 2 channel Tri-wire | ||||
Output | Isolation RS232/RS485 output, 2 channel isolation OCT output, | ||||
Communication Protocols | Compatible with METER-BUS protocol, MODBUS protocol, Fuji | ||||
Structure of UFM
Single point measuring (Several optional secondary meter for long distance display and parameter setup) |
|
Network structure (For remote monitor and data collector) |
RS-485 bus (transmission distance up to 1000m ) 24V power supply |
|
Note:power supply and communicate with four-core cable (Red: 24V+, Black: 24V-, White: 485+, Green: 485-) |


Fax:86-631-5690222
Email: info@ultrasonicscn.com
Skype: longruncn
24 hours service:
0086-0151-63172843