Portable ultrasonic flow meter sensor installation

1 portable ultrasonic flow meter installation options

Insert sensor applied in DN80mm above the pipe, typically using Z method installation.

Only when the installation space is insufficient, less than DN200mm pipeline can choose to use the V method installation, more than DN200mm pipeline can use parallel insertion sensor.

2 portable ultrasonic flow meter to measure the parameter settings, to get the installation distance

At the beginning of the measurement is required prior to the flow of an initial set, usually 10-26 menu item by item set ( M39 menu with multiple languages are available ), after the completion of installation in the M25 can get sensor mounting distance.

For parallel insertion sensor, probe options for PI meter probe: probe pipe angle of 0 °; static state fluid length is 0mm; probe the straight-line distance between 200mm-300mm choose between, to the actual installation results to determine a single sound, including the delay time 0us.

For the standard insertion style sensor using Z method, the installation distance = -10mm. diameter