Separate Fixed Calorimeter / LRC-2000S

Separate Fixed Calorimeter
  • LRC-2000S is wall-mount economical ultrasonic heat/cold meter. It is comprised of wall-mount ultrasonic flow meter and a pair of temperature sensors PT100.

 

Features

l High Accuracy measuring 
Linearity: better than 0.5%, Repeatability: better than 0.2%, Accuracy: better than ±1%
l Wide measuring range
Several types transducer for selection, measuring pipe size from DN15mm to DN6000mm
 High Reliability   
Adopt low voltage, multi-pulse technology to improve accuracy, useful life and reliability
l Strong Anti-interference  
Dual-balance signal differential receiver/driver circuit to avoid interference of converter,TV ower, high voltage line etc.    
l Powerful Recording Function
Automatically record the following data:
1.The totalizer data of the last 512 days/128 months/10 years
2.The time and corresponding flow rate of the last 64 times of power on and off events 
3. The working status of the last 32 days 
l With the clamp on ultrasonic temperature transducer

Measuring Diagram of heat meter 

Structure of clamp-on measuring   

Structure of  insertion measuring   

Structure of Prover Section measuring   


Optional Main unit

Wall-mount (LRC-2000SB) 
For hanging installation
Size: 178 x 165 x 55mm 

Panel-mount (LRC-2000SS)
For instrument panel installationPanel 
Size: 84 x 168mm 

Explosion-proof (LRC-2000SD)
Explosive-proof Grade is DIIBT4
Size: 285 x 265 x 90mm 

    

Optional Flow Transduce

Optional Transduers

Model

Measuring Range

Liquid Temperature

Accuracy

Clamp-on

TS-2(small size)

DN15 -100mm

0C ° ∼ 90C °

Better than

±1%

TM-1(medium size)

DN50 -1000mm

TL-1(large size)

DN300 -6000mm

High-tem clamp-on

THS-1(small size)

DN15 -100mm

0C ° ∼ 160C °

THM-1(medium size)

DN300 -1000mm

Insertion

TC-1(standard)

DN80 -6000mm

0C ° ∼ 90C °

 

Better than

±1%

TLC-2(lengthen)

Prover Section

Prover Section

DN15 -1000mm 
(see appendix 2)

0C ° ∼ 90C °

Better than

±0.5%

Power Supply

 DC8-36V or AC220V

Input

 3 channel 4-20mA analog input

Output

 Isolation RS-232/RS-485 output, 2 channel isolation OCT 
  output: 1 channel isolation 4-20mA output (two-wire system)

Communication Protocols

 Compatible with METER-BUS, MODBUS, Fuji extended protocol and 
  general water meter protocol.



Optional Temperature Transducer

Clamp on temperature transducer PT100

No need to cut off water, no pressure loss

Insertion temperature transducer PT100

Need to cut off water, no pressure loss